Skip to Main Content
CONNECT feedback portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about CONNECT products and services. All of the feedback you share here is monitored and reviewed by the CONNECT product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for CONNECT. For links to our other feedback portals, please see RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Data Retention configuration for EDS SDS

We have no information regarding data retention. This could be clarified. Data retention should be better configurable as of now, only the stream size can be configured just by estimation. Provide a sizing and calculation tool for Edge Data Store ...
Hans-Otto Weinhold over 2 years ago in AVEVA™ Edge Data Store / Historian 0 No status

host adapter(s) as a service

SaaS solution for customers with benefits thereof.
Glenn Moffett almost 3 years ago in AVEVA™ Adapters / General 1 No status

EDS: Modbus Serial Connector

Ability for Modbus Serial connector to write data to Edge Data Store.
Guest about 4 years ago in AVEVA™ Edge Data Store / Ingress 1 Declined

Do not bundle PI Adapters with EDS

Reduce the footprint of EDS by not bundling adapters with EDS but instead have them be a separate installation so only the desired adapters end up being installed on the device. It will also allow easier for a clearer process when an adapter needs...
Guest about 4 years ago in AVEVA™ Edge Data Store / Installation 1 Future consideration

Deployment of OCS in Norway

Deploy OCS in Norway We need to make sure the servers that our data resides on is located within Norway.
Guest about 4 years ago in General / Regional Deployments 0 No status

read files from AWS S3, Azure storage and Google Cloud Storage

For example, model inference data is written to storage and required destination is a PI System.
Guest about 4 years ago in AVEVA™ Adapters / New Connectivity 0 No status

Expand Healthpoint (Device Status) Information of the PI Adapter for Modbus TCP from Component to "Device" Level

When configuring PI Modbus TCP adapter you first define a component level and under this type you define your different devices/machines/sensors. In case of a broken connection to one of the devices the healthpoints currently only deliver the stat...
Guest almost 3 years ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 No status

Documentation of EDS Modbus TCP Adapter needs to be updated on removed 32-bit register support for Modbus TCP Adapter

Challenge: The current version of PI Adapter for Modbus TCP does not any longer support 32-bit Holding/Input registers as this is outside of the Modbus specifications. However, in some cases, 32-bit register values have to be read from 16-bit regi...
Hans-Otto Weinhold about 3 years ago in AVEVA™ Edge Data Store / Ingress 0 Planned

Support for "RTU over TCP" for Modbus Adapter using MBAP header

Challenge: Today, the PI Adapter for Modbus TCP does not natively support " RTU over TCP". It does support Modbus TCP, so as long as the "bridge" properly converts Modbus RTU to Modbus TCP (including the MBAP header), it should work fine. If the b...
Hans-Otto Weinhold about 3 years ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 No status

Provide additional time formatting options for RDBMS Queries

Background: Today we are collecting data from our AspenTech IP21 Server thorugh the PI Adapter for OPC UA and the related AspenTech OPC UA Server. This works perfectly fine for analogue data but not for data which is providing us equipment status ...
Hans-Otto Weinhold about 3 years ago in AVEVA™ Adapters / AVEVA Adapter for RDBMS 1 Tell us more