To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for CONNECT. For links to our other feedback portals, please see RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Allow session persistence to support true QoS 2 data collection and backfill of events after a data source disconnection

It appears that regarding Session Persistence (persistent vs clean session), the Adapter hardcodes setting the Clean Session Flag for the generic data source (Sparkplug doesn’t QoS 2 nor session persistence) to true. This should be a user-defined ...
Daniel Lopez 7 months ago in AVEVA™ Adapters / AVEVA Adapter for MQTT 1 No status

Increased Editability of Virtual Table Fields

Currently, the only editable field in the Virtual Table settings is the Refresh Interval because modifying other fields render the table invalid, and require re-initialization or rebuilding. Other fields like Retrieval Mode, Retrieval Interval, an...
Dennica Mitev 7 months ago in Data Platform Integration / Virtual Tables & Shares 0 No status

Classic Mode for Adapters

One of the big issues we have with adapters (outside of the lack of write capability) is not having the same control over creating and editing tags that we have with PI interfaces. As we talked about the adapter automatically creates PI tags or us...
Guest over 3 years ago in AVEVA™ Adapters / General 5 Future consideration

Automatic Configuration Sync between failover adapters

When adapters in a failover group, any changes to configuration need to be manually synchronised between the adapters. Without automation, this could lead to misaligned configuration causing data collection issues.
Mike Horrocks 5 months ago in AVEVA™ Adapters / General 0 No status

Please add a feature for the OPC UA adapter to enable the adapter to only store values with a good status or rather filtering out bad values

When receiving bad values from the OPC UA Server to the adapter there is no option to filter out bad values. So these values get stored in the Data Archive and are causing problems with analyses (e.g. expression or Event Frame generation). At the ...
Guest over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 No status

Native MQTT Publishing (Egress) to Support Unified Namespace (UNS) Architectures

Description & Use Case: As the manufacturing industry shifts toward Industry 4.0 and Unified Namespace (UNS) architectures, data must flow seamlessly between all systems in a publish/subscribe model. The AVEVA PI System is exceptional at inges...
Guest 7 months ago in AVEVA™ Adapters / AVEVA Adapter for MQTT 0 No status

Adapter to failover when there is egress issue

When connection to the datasource are all good for all the adapter failover members, but the primary adapter having issue connecting to the PI web API (egress) for example, adapter does not failover. Unlike PI Interface UNIINT failover, when there...
Ee Sheing Lee about 3 years ago in AVEVA™ Adapters / General 2 No status

Error handling for OPC UA Server nodes with "Null" data type

Using a combination of Honeywell Experion OPC UA and the Aveva OPC UA Adapter, we have observed that when an instrument physically fails in the field or goes offline / stops sending communication to the Experion server, it may appear in the Honeyw...
ChrisMcKee 9 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 Evaluating

Enable Multiple PI to CONNECT agents for one PI Data Archive

Aside from our main AF Server setup used for numerous use cases like energy, OEE, etc, we have created a second environment of AF Server / AF Analysis / SQL Server to isolate the monitoring of a critical process. We are still making use of a singl...
Christian Leroux over 3 years ago in PI to CONNECT / General 0 No status

Support PI formula attributes for the PI to CONNECT transfer

Problem: Currently, formula attributes from PI assets are not replicated. Formula attributes are important structures for machine data as well as business logic and therefore indispensable for countless applications of CONNECT Data Services and th...
Marco Diepold 2 months ago in PI to CONNECT / General 0 No status