Skip to Main Content
CONNECT feedback portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about CONNECT products and services. All of the feedback you share here is monitored and reviewed by the CONNECT product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for CONNECT. For links to our other feedback portals, please see RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Allow Adaptors to run in Docker

Allow Adaptors to run in Docker. This would ease the roll-out and management of adaptors. Also new Cisco switches now allow Docker instances on the switch, limiting the need for extra hardware.
Erik Prins over 2 years ago in AVEVA™ Adapters / General 2 Already exists

Configuration reconnection (retry) time on the adapter

OPC UA adapter takes 5min by default to reconnect to a load balanced PI Web API pair which failed over.
Guest over 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Rename services to reflect the renaming of the product

AVEVA Adapters were previously called "PI Adapters", but the name of any AVEVA Adapter service begins with "PIAdapter". The PI To CONNECT Agent was previously called the "PI To Data Hub Agent", but the service name is still "PIToDataHubAgent". I'm...
Kenneth Barber 3 months ago in AVEVA™ Adapters / General 0 No status

Enable AVEVA Adapter for OPC UA to work with OPC UA Servers that only allow Dynamic Addressing and Virtual Browsing

Some OPC UA Servers have the concept of Dynamic Namespace Addressing and Virtual Browsing. The UA Nodes do not exist in the OPC UA Address Space. Nodeids are created\added to the Address Space only when a Client makes a request for the NodeIds thr...
Guest 8 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Allow setting interpolation type in Adapters

We would like to be able to specify the interpolation type (linear vs step) when Adapter creates tags in Archive.
Guest over 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

View PI Adapter log files via REST calls

We would like to be able to see the adapter log files via REST calls. Going to the machine itself to view is problematic because of remoting into the router and then going into the container to view. I think in a lot of containerized situations a ...
Guest about 4 years ago in AVEVA™ Adapters / General 3 Tell us more

PI Adapter for Structured Data Files support for files with format: tag,timestamp,value

input file format is (where identifier is the tag/stream name): identifier, timestamp,value identifier, timestamp,value ...
Guest about 4 years ago in AVEVA™ Adapters / AVEVA Adapter for Structured Data Files / General 3 Tell us more

change data capture, data change, data update support

For example, when changes are made via recalculation, provide a method to indicate data has changed.
Glenn Moffett 9 months ago in Data Views / General 0 No status

UOM lost on restart & missing UOM definition at data collection level

Description When using the ModbusTCP adapter (seems other Adapters impacted): Data is ingested into CDS as a stream A Unit of Measure (UOM) can be manually assigned to the stream in CDS or EDS. But on adapter restart, the UOM is automaticall...
Jean-Philippe Tricart 6 months ago in AVEVA™ Adapters / General 0 No status

databricks to CONNECT

Write data to CONNECT from databricks - including calculation results, model output.
Glenn Moffett 9 months ago in Data Platform Integration / New Integrations 0 No status