To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for CONNECT. For links to our other feedback portals, please see RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Adapter for RDBMS to support multiple rows with same "Timestamp" colum as IndexColumn

As of version 1.x, with the IndexColumn being specified in the dataselection, the Adapter will require that each row in the source Database to have its own unique timestamp. If there are multiple rows with the same timestamp, first value with the ...
Ee Sheing Lee about 3 years ago in AVEVA™ Adapters / AVEVA Adapter for RDBMS 4 Tell us more

Automated discovery on a schedule

Enable Regular Discovery: While not continuous by default, discovery can be scripted or scheduled to run periodically for dynamic environments include this as a feature, so that automatic discovery and automatic addition of new discoveries can be ...
Guest 9 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 No status

Add the option "Ignore Bad_WaitingForInitialData Status"

In the connectors there was the option "Ignore Bad_WaitingForInitialData Status", as described here. For gen 1 there was a need to edit the config files directly, and in gen 2 the option was integrated into the UI. Instead for the adapter I recent...
Guest almost 3 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

processor rate(s) for Processor properties of Modbus Adapter Service Health

Visualize and understand usage when trended with other diagnostic properties.
Glenn Moffett 5 months ago in AVEVA™ Adapters / General 1 No status

OMF Egress health to include stream count

Validate stream count for scenarios where there are multiple Components
Glenn Moffett 5 months ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 No status

displayname/localname for identifier that excludes namespace and data type

Example: OPC UA Server 'Name': 2.0:W-HVAC-AC-1-IO!Wtot Namespace: 2 Datatype: 0 Identifier: W-HVAC-AC-1-IO!Wtot OPC UA Server 'DisplayName': W-HVAC-AC-1-IO!Wtot OPC UA Adapter {Identifier} returns: 2.0:W-HVAC-AC-1-IO!Wtot Required stream name: W-H...
Glenn Moffett about 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

CONNECT Integration with Grafana

Provide an integration with Grafana so that OCS data can be easily included alongside data from other sources in a simple-to-configure, but powerful visualization tool
Guest about 4 years ago in Data Platform Integration / New Integrations 1 No status

Support of complex streams with PI Adapter for RDBMS with free attribute selection

Background: Today we are collecting data from our AspenTech IP21 Server thorugh the PI Adapter for OPC UA and the related AspenTech OPC UA Server. This works perfectly fine for analogue data but not for data which is providing us equipment status ...
Hans-Otto Weinhold about 3 years ago in AVEVA™ Adapters / AVEVA Adapter for RDBMS 2 Planned

Add a parameter for the Adapter to increase the Keep-Alive wait time

Currently, there is no parameter on the Adapter side to increase the Keep-Alive wait time. It would be best to add parameter for the Adapter to increase the Keep-Alive wait time.
Alexa Derago 5 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Configure refresh interval start time

End-users of created virtual tables expect updates at specific times.Request would enable user to indicate when refresh should occur. For example, for daily refresh, indicating a time of 5am, so that end-users can query the updated table when they...