Skip to Main Content
CONNECT feedback portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about CONNECT products and services. All of the feedback you share here is monitored and reviewed by the CONNECT product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for CONNECT. For links to our other feedback portals, please see RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

For PI Points created by AVEVA Adapters, use the point class "base" instead of "classic" if the PI Point does not use "classic"-specific PI Point attributes

When an AVEVA Adapter creates a new PI Point, it always uses the point class "classic", even if none of the attributes that are specific to this point class are ever used. Instead, AVEVA Adapters should create PI Points using the point class "base...
Kenneth Barber 2 months ago in AVEVA™ Adapters / General 0 No status

Be able to configure history recovery through the AVEVA Adapter Configuration Utility for AVEVA Adapters that support history recovery (e.g. OPC UA, RDBMS)

This is item #3 of this suggestion, posted as its own suggestion.
Kenneth Barber 2 months ago in AVEVA™ Adapters / AVEVA Adapter Configuration Utility 0 No status

Be able to configure the Client Failover Service through the AVEVA Adapter Configuration Utility or a separate optional GUI program

The Client Failover Service suffers from the same issues as AVEVA Adapters before the AVEVA Adapter Configuration Utility was released: you need to constantly check against the documentation and make sure that you spelled parameters and their valu...
Kenneth Barber 2 months ago in AVEVA™ Adapters / AVEVA Adapter Configuration Utility 0 No status

Allow session persistence to support true QoS 2 data collection and backfill of events after a data source disconnection

It appears that regarding Session Persistence (persistent vs clean session), the Adapter hardcodes setting the Clean Session Flag for the generic data source (Sparkplug doesn’t QoS 2 nor session persistence) to true. This should be a user-defined ...
Daniel Lopez 7 months ago in AVEVA™ Adapters / AVEVA Adapter for MQTT 1 No status

Increased Editability of Virtual Table Fields

Currently, the only editable field in the Virtual Table settings is the Refresh Interval because modifying other fields render the table invalid, and require re-initialization or rebuilding. Other fields like Retrieval Mode, Retrieval Interval, an...
Dennica Mitev 7 months ago in Data Platform Integration / Virtual Tables & Shares 0 No status

Classic Mode for Adapters

One of the big issues we have with adapters (outside of the lack of write capability) is not having the same control over creating and editing tags that we have with PI interfaces. As we talked about the adapter automatically creates PI tags or us...
Guest over 3 years ago in AVEVA™ Adapters / General 5 Future consideration

Automatic Configuration Sync between failover adapters

When adapters in a failover group, any changes to configuration need to be manually synchronised between the adapters. Without automation, this could lead to misaligned configuration causing data collection issues.
Mike Horrocks 5 months ago in AVEVA™ Adapters / General 0 No status

Please add a feature for the OPC UA adapter to enable the adapter to only store values with a good status or rather filtering out bad values

When receiving bad values from the OPC UA Server to the adapter there is no option to filter out bad values. So these values get stored in the Data Archive and are causing problems with analyses (e.g. expression or Event Frame generation). At the ...
Guest over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 No status

Native MQTT Publishing (Egress) to Support Unified Namespace (UNS) Architectures

Description & Use Case: As the manufacturing industry shifts toward Industry 4.0 and Unified Namespace (UNS) architectures, data must flow seamlessly between all systems in a publish/subscribe model. The AVEVA PI System is exceptional at inges...
Guest 7 months ago in AVEVA™ Adapters / AVEVA Adapter for MQTT 0 No status

Adapter to failover when there is egress issue

When connection to the datasource are all good for all the adapter failover members, but the primary adapter having issue connecting to the PI web API (egress) for example, adapter does not failover. Unlike PI Interface UNIINT failover, when there...
Ee Sheing Lee about 3 years ago in AVEVA™ Adapters / General 2 No status