To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for CONNECT. For links to our other feedback portals, please see RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Adapter to failover when there is egress issue

When connection to the datasource are all good for all the adapter failover members, but the primary adapter having issue connecting to the PI web API (egress) for example, adapter does not failover. Unlike PI Interface UNIINT failover, when there...
Ee Sheing Lee almost 3 years ago in AVEVA™ Adapters / General 2 No status

Classic Mode for Adapters

One of the big issues we have with adapters (outside of the lack of write capability) is not having the same control over creating and editing tags that we have with PI interfaces. As we talked about the adapter automatically creates PI tags or us...
Guest over 3 years ago in AVEVA™ Adapters / General 5 Future consideration

Add a parameter to disable NTLM authentication

On the "Health endpoints parameters" page of the documentation of any AVEVA Adapter, it states that Negotiate (i.e. try Kerberos first and fall back to NTLM if that fails) will be used if a username/password pair and a clientId/clientSecret pair a...
Guest 2 months ago in AVEVA™ Adapters / General 0 No status

Better control and monitoring of usage

As a CONNECT data services administrator, I want to track daily streams accessed by both individual users and applications, so that I can better understand the usage incurred by each CONNECT consumer. Additionally, I need the ability to allocate u...
Max McKay almost 2 years ago in General / Account Management 1 No status

Enable AVEVA Adapter for OPC UA to work with OPC UA Servers that only allow Dynamic Addressing and Virtual Browsing

Some OPC UA Servers have the concept of Dynamic Namespace Addressing and Virtual Browsing. The UA Nodes do not exist in the OPC UA Address Space. Nodeids are created\added to the Address Space only when a Client makes a request for the NodeIds thr...
Guest 7 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Support Custom Units of Measure (UOMs)

The ability to define custom units of measure (UOMs) within OCS.
Guest about 4 years ago in Streams / Sequential Data Store (SDS) 3 No status

Allow AVEVA Adapter for Modbus TCP to collect data on INT64 and UINT64 registers

Certain equipment is providing energy data under INT64 or UNIT64 register types. However, the Adapter currently only supports FLOAT64, which is not compatible. We want to be able to configure the Adapter for Modbus TCP to collect data on INT64 and...
Guest 12 months ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 Future consideration

Design some UI for PI Adaptors

Design some UI for PI Adaptors, so it will be user friendly to configure the data source or data reading configurations etc. It is really hard to configure or troubleshoot an issue in PI Adaptor without Proper UI.
Guest almost 2 years ago in AVEVA™ Adapters / AVEVA Adapter for MQTT 2 No status

Add parameter to limit the amount of data retrieved in a Get Updates request - Change broker

Add a parameter that we could pass in the Get Updates request to set a maximum number of events returned since the bookmark https://docs.aveva.com/bundle/connect-data-services-developer/page/api-reference/change-broker/change-broker-updates.html
Guest about 1 year ago in Streams / Sequential Data Store (SDS) 0 No status

Configuration reconnection (retry) time on the adapter

OPC UA adapter takes 5min by default to reconnect to a load balanced PI Web API pair which failed over.
Guest about 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status