Skip to Main Content
CONNECT feedback portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about CONNECT products and services. All of the feedback you share here is monitored and reviewed by the CONNECT product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for CONNECT. For links to our other feedback portals, please see RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Provide GUI for Configuration

Edge Data Store would require a GUI for configuration and health status to work more efficiently to set it up with too many efforts. The GUI should allow to set up the connection to the Data sources of the included PI Adapters, provide OPC UA brow...
Guest over 2 years ago in AVEVA™ Edge Data Store / General 1 No status

PI Adapter for OPC UA should send the previous value when it has been with the same value for a long time

"This enhancement request proposes a solution to address the issue of data interpolation between two values far apart in time in adapter data collection. The suggestion is to include the value right before the new data point, ensuring the fidelity...
Fabio Dani over 3 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 No status

API to check Adapter buffer statistics

We can check buffer statistics with PI Buffer subsystem (pibufss -cfg, qs) and also with PI Connector/Relay, to verify whether Buffer is healthy, events in queue and etc.Adapter does not has any API to check this.
Ee Sheing Lee almost 3 years ago in AVEVA™ Adapters / General 1 No status

Add parameter "Max Monitored Items per Subscription"

The connector for OPC UA includes a parameter “Max Monitored Items per Subscription”, which is very helpful in managing UA servers which may have limits on the maximum items per subscription. This parameter needs to also be available in the adapters.
Guest almost 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 3 Future consideration

EDS: OPC DA Connector

Ability for OPC DA connector to write data to Edge Data Store.
Guest about 4 years ago in AVEVA™ Edge Data Store / Ingress 1 Declined

Store Images & Pictures into OCS

Ability to store images as time bound data into OCS, and retrieve the images for viewing or modeling/analysis. Example scenario: a thermal camera takes a picture of a furnace and the image is used to extract data and performance KPIs about the f...
Guest about 4 years ago in Streams / Sequential Data Store (SDS) 1 No status

Allow MQTT adapter to parse timestamps in local time without specifying a timezone suffix to each timestamp

We would like the MQTT Adapter to be able to interpret timestamps in local time without needing to explicitly state the timezone or UTC offset in each timestamp, but for the adapter to always interpret the timestamps as being in a specific timezon...
Guest about 4 years ago in AVEVA™ Adapters / AVEVA Adapter for MQTT 0 No status

Expand PI Adapters to be installed on RedHat/CentOS

No description provided
Guest about 4 years ago in AVEVA™ Adapters / General 4 Tell us more

Allow default settings (eg. disable compression) for tags created by Adapters

We would like to be able to specify default settings for tags created by the adapters. This would include things such as disabling compression for tags on this adapter (without disabling it as the default for all new tags on the Data Archive). Thi...
Guest about 4 years ago in AVEVA™ Adapters / General 0 No status

PI Adapter for GE e-terrahabitat/HabConnect

We need a new robust product to support data transfer between GE e-terrahabitat/HabConnect and PI. This product would need to support the following: Highly available remote management/deployment multiple instances on a single node (to support larg...
Guest about 3 years ago in AVEVA™ Adapters / New Connectivity 0 No status