To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for CONNECT. For links to our other feedback portals, please see RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Compression on CONNECT to PI related tags

The tags use the default compression settings since they are automagically created through PI WebAPI if CONNECT to PI agent starts sending the transfer. This can mean that there is another compression applied to the tags. But as we are already cop...
Hans-Otto Weinhold over 1 year ago in CONNECT to PI 0 No status

Rename services to reflect the renaming of the product

AVEVA Adapters were previously called "PI Adapters", but the name of any AVEVA Adapter service begins with "PIAdapter". The PI To CONNECT Agent was previously called the "PI To Data Hub Agent", but the service name is still "PIToDataHubAgent". I'm...
Kenneth Barber 3 months ago in AVEVA™ Adapters / General 0 No status

PI to CONNECT should have a verification tool to make sure there are no gaps in the data

When using PI to CONNECT there might be errors in the transfer due to disconnections or other network issues. Ideally PI to CONNECT would have a tool to verify if the data was properly transferred by checking the data.
Fabio Dani about 1 year ago in PI to CONNECT / General 0 No status

Ua Server force failover / improve failover logic

Let me preface this by saying that I know it is a workaround for a non-compliance with the OPC UA specifications. The point is that the situation described below is unfortunately all too common and the workaround is needed. It often happens that t...
Guest about 3 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 No status

Prevent PI Adapter for OPC UA from modifying/override stream overrides and metadata upon restart

Problem: I have configured PI Adapter for OPC UA to collect data from an OPC UA Server. Since UoMs are not assigned properly, I created stream overrides in AVEVA Data Hub to assign the proper UoM to the particular stream. I also associated stream ...
Hans-Otto Weinhold over 3 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 4 In development

Stream lists should always be alphabetical by default

Today it is hard to find Streams without using the filtering. You should not have to filter to scroll through the list and find related Stream data.
Guest 3 months ago in Streams / Sequential Data Store (SDS) 0 No status

UOM lost on restart & missing UOM definition at data collection level

Description When using the ModbusTCP adapter (seems other Adapters impacted): Data is ingested into CDS as a stream A Unit of Measure (UOM) can be manually assigned to the stream in CDS or EDS. But on adapter restart, the UOM is automaticall...
Jean-Philippe Tricart 6 months ago in AVEVA™ Adapters / General 0 No status

PI Adapter for MQTT should include MQTT broker

Having to deal with a MQTT broker between the data source and the PI Adapter adds a single point of failure to the data handling and weakens the data flow end-to-end. From the data source we can guarantee that the data will reach the MQTT broker, ...
Guest about 4 years ago in AVEVA™ Adapters / AVEVA Adapter for MQTT 0 No status

PI Adapter for OPC UA data conversion

As a PI System Administrator, I would like to be able to apply conversion factors to the data that is being gathered from our OPC UA server. This would allow us to get data in the format/units we'd like, without requiring extra tags and/or calcula...
Guest about 4 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 2 No status

Allow Transfer Edit

The current version of the Transfer does not allow edits. This makes things difficult when project evolves and more streams need to be added to the transfer.