To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for CONNECT. For links to our other feedback portals, please see RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Please add a feature for the OPC UA adapter to enable the adapter to only store values with a good status or rather filtering out bad values

When receiving bad values from the OPC UA Server to the adapter there is no option to filter out bad values. So these values get stored in the Data Archive and are causing problems with analyses (e.g. expression or Event Frame generation). At the ...
Guest over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 No status

Configuration reconnection (retry) time on the adapter

OPC UA adapter takes 5min by default to reconnect to a load balanced PI Web API pair which failed over.
Guest over 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 No status

PI Adapter for OPC UA data conversion

As a PI System Administrator, I would like to be able to apply conversion factors to the data that is being gathered from our OPC UA server. This would allow us to get data in the format/units we'd like, without requiring extra tags and/or calcula...
Guest over 4 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 2 No status

Allow setting interpolation type in Adapters

We would like to be able to specify the interpolation type (linear vs step) when Adapter creates tags in Archive.
Guest over 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Enable AVEVA Adapter for OPC UA to work with OPC UA Servers that only allow Dynamic Addressing and Virtual Browsing

Some OPC UA Servers have the concept of Dynamic Namespace Addressing and Virtual Browsing. The UA Nodes do not exist in the OPC UA Address Space. Nodeids are created\added to the Address Space only when a Client makes a request for the NodeIds thr...
Guest 9 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Add Warning when there are multiple rows at the same timestamp with the same Field

Add a Warning when there are multiple rows with the same Field to prompt user to add additional context via Grouping Fields, Identifying Field, etc. Currently, if the Identifying Field and Grouping Fields are set in a way that results in multiple ...
Miranda Hill 3 months ago in Data Views / General 0 No status

Option to search/select only | Value properties in the Add Data Fields window

Currently, for Data Views with Assets queries, when searching data fields with Summary Type Filter Value and Filter by text option of Value Field Name, it's pulling all properties that contain value. If property name includes "value" it is returne...
Miranda Hill 3 months ago in Data Views / General 0 No status

Ua Server force failover / improve failover logic

Let me preface this by saying that I know it is a workaround for a non-compliance with the OPC UA specifications. The point is that the situation described below is unfortunately all too common and the workaround is needed. It often happens that t...
Guest over 3 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 No status

Prevent PI Adapter for OPC UA from modifying/override stream overrides and metadata upon restart

Problem: I have configured PI Adapter for OPC UA to collect data from an OPC UA Server. Since UoMs are not assigned properly, I created stream overrides in AVEVA Data Hub to assign the proper UoM to the particular stream. I also associated stream ...
Hans-Otto Weinhold over 3 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 4 In development

Stop Virtual Table Refreshes or Materializations

When attempting to do a Manual Refresh of an existing Virtual table with a known data gap or attempting to materialize a new Virtual Table in AVEVA CONNECT, have ran into the issue where the either option can run much longer than expected (days fo...
Guest 3 months ago in Data Views / General 0 No status