To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for CONNECT. For links to our other feedback portals, please see RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Add Warning when there are multiple rows at the same timestamp with the same Field

Add a Warning when there are multiple rows with the same Field to prompt user to add additional context via Grouping Fields, Identifying Field, etc. Currently, if the Identifying Field and Grouping Fields are set in a way that results in multiple ...
Miranda Hill 28 days ago in Data Views / General 0 No status

Option to search/select only | Value properties in the Add Data Fields window

Currently, for Data Views with Assets queries, when searching data fields with Summary Type Filter Value and Filter by text option of Value Field Name, it's pulling all properties that contain value. If property name includes "value" it is returne...
Miranda Hill 28 days ago in Data Views / General 0 No status

Allow the PI Point description to not be populated by the adapter

Implement a configuration flag that allows one to NOT synchronize description from OPC UA server into PI Tag. In instances where the description is empty "", the description cannot be set in PI. Similarly, the description on the OPC UA Server sid...
Guest about 4 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 17 Planned

Start/stop components to be retained on restart

Currently it is possible to stop a component for a running adapter. However, if the adapter is restarted the component will automatically start up. It would allow for extra control during commissioning, downtime, incidents, etc. to be able to disa...
Mike Horrocks 10 months ago in AVEVA™ Adapters / General 0 No status

Include buffering metrics in adapter health

In the OmfEgress component in adapter health the metrics are limited to DeviceStatus, and IO rate. Another key metric for this component is the buffering state. To keep it simple it would be useful to have the number of events in the buffer. This ...
Mike Horrocks over 1 year ago in AVEVA™ Adapters / General 1 No status

Bitmask Functionality in AVEVA PI OPC UA Adapter

During the migration from the PI OPC DA Interface to the AVEVA PI OPC UA Adapter, we noticed that the ability to apply bitmasks to incoming values is no longer supported. This functionality is critical in many existing implementations, especially ...
Guest about 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 Future consideration

Support https instead of http only

No description provided
Guest about 4 years ago in AVEVA™ Adapters / General 2 Future consideration

AVEVA Adapter for MQTT to support payload compression from the source MQTT SparkplugB device

AVEVA Adapter for MQTT (SparkplugB data source) to support payload compression from the source MQTT SparkplugB device. Compression can be enabled at the Edge, for example Enable compression and/or aliasing at the Edge: For compression, either the ...
Ee Sheing Lee 4 months ago in AVEVA™ Adapters / AVEVA Adapter for MQTT 1 No status

Stop Virtual Table Refreshes or Materializations

When attempting to do a Manual Refresh of an existing Virtual table with a known data gap or attempting to materialize a new Virtual Table in AVEVA CONNECT, have ran into the issue where the either option can run much longer than expected (days fo...
Guest about 1 month ago in Data Views / General 0 No status

Allow files to be processed similarly to, or better than, the PI Connector For UFL (in particular, allow data to be manipulated before using or archiving it)

The AVEVA Adapter For Structured Data Files is supposed to be the successor to the PI Connector For UFL, but they work differently enough that each can handle certain types of files better than the other. The AVEVA Adapter For Structured Data File...
Guest about 1 month ago in AVEVA™ Adapters / AVEVA Adapter for Structured Data Files 1 No status