To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for CONNECT. For links to our other feedback portals, please see RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Stop Virtual Table Refreshes or Materializations

When attempting to do a Manual Refresh of an existing Virtual table with a known data gap or attempting to materialize a new Virtual Table in AVEVA CONNECT, have ran into the issue where the either option can run much longer than expected (days fo...
Guest 2 months ago in Data Views / General 0 No status

Allow files to be processed similarly to, or better than, the PI Connector For UFL (in particular, allow data to be manipulated before using or archiving it)

The AVEVA Adapter For Structured Data Files is supposed to be the successor to the PI Connector For UFL, but they work differently enough that each can handle certain types of files better than the other. The AVEVA Adapter For Structured Data File...
Kenneth Barber 2 months ago in AVEVA™ Adapters / AVEVA Adapter for Structured Data Files 1 No status

Allow AVEVA Adapter for Modbus TCP to collect data on INT64 and UINT64 registers

Certain equipment is providing energy data under INT64 or UNIT64 register types. However, the Adapter currently only supports FLOAT64, which is not compatible. We want to be able to configure the Adapter for Modbus TCP to collect data on INT64 and...
Alexa Derago about 1 year ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 Future consideration

Have the option to discover new data streams, auto-select them, and save data retrieved for them, all with a single query to the data source, similar to PI Connectors

Background + problem When PI Connector tries to save data for a tag that does not already exist (e.g. data for a new piece of equipment), it will create that tag automatically. This is very convenient, but it sometimes led to issues where data tha...
Kenneth Barber 2 months ago in AVEVA™ Adapters / General 0 No status

Classic Mode for Adapters

One of the big issues we have with adapters (outside of the lack of write capability) is not having the same control over creating and editing tags that we have with PI interfaces. As we talked about the adapter automatically creates PI tags or us...
Guest over 3 years ago in AVEVA™ Adapters / General 5 Future consideration

Please add a feature for the OPC UA adapter to enable the adapter to only store values with a good status or rather filtering out bad values

When receiving bad values from the OPC UA Server to the adapter there is no option to filter out bad values. So these values get stored in the Data Archive and are causing problems with analyses (e.g. expression or Event Frame generation). At the ...
Guest over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 No status

Before publishing documentation, please review it, from start to finish, to catch and fix most issues

Whether I was trying to learn about a product before using it or trying to configure a product, I ended up reading most of the documentation of several new or somewhat new AVEVA products, including: AVEVA Adapter For RDBMS AVEVA Adapter For St...
Kenneth Barber 2 months ago in AVEVA™ Adapters / Help / Documentation / Videos 0 No status

Replace the Expand All/Collapse All menu of components with equivalent buttons

The Expand All/Collapse All menu is meant to be more convenient than expanding or collapsing all components individually. However, it currently takes a click, a careful mouse movement, and another click to select an option. To make this even easie...
Kenneth Barber 2 months ago in AVEVA™ Adapters / AVEVA Adapter Configuration Utility 0 No status

Be able to duplicate and disable components

The ability to duplicate components would give a better starting point for components that need to be configured similarly. For example, I like components that collect little data and do so infrequently to have no data filter and have the logging ...
Kenneth Barber 2 months ago in AVEVA™ Adapters / AVEVA Adapter Configuration Utility 0 No status

Allow session persistence to support true QoS 2 data collection and backfill of events after a data source disconnection

It appears that regarding Session Persistence (persistent vs clean session), the Adapter hardcodes setting the Clean Session Flag for the generic data source (Sparkplug doesn’t QoS 2 nor session persistence) to true. This should be a user-defined ...
Daniel Lopez 7 months ago in AVEVA™ Adapters / AVEVA Adapter for MQTT 1 No status