To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for CONNECT. For links to our other feedback portals, please see RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Native MQTT Publishing (Egress) to Support Unified Namespace (UNS) Architectures

Description & Use Case: As the manufacturing industry shifts toward Industry 4.0 and Unified Namespace (UNS) architectures, data must flow seamlessly between all systems in a publish/subscribe model. The AVEVA PI System is exceptional at inges...
Guest 6 months ago in AVEVA™ Adapters / AVEVA Adapter for MQTT 0 No status

PI Adapter for SNMP

Write a PI Adapter that supports the SNMP protocol and is capable of writing data to EDS, PI, and OCS.
Guest about 4 years ago in AVEVA™ Adapters / New Connectivity 4 Evaluating

Add failover / high availability for the PI to AVEVA Data Hub Transfer Agent

Right now, the Transfer Agent is a single point of failure. We need to be able to install at least one additional Transfer Agent, on a separate host, so that we can guarantee that our PI System data will arrive in AVEVA Data Hub. This will also al...
Daniel Lopez almost 3 years ago in PI to CONNECT / General 0 No status

Sampling/Publishing Interval parameters to be part of Data Selection description

When configuring the AVEVA Adapters in general, we would find more convenient to be able to define the ‘Sampling Interval’ and 'Publishing Interval' parameters inside the ‘Data Selection’ configuration per each data stream. For instance, when desc...
Christian Leroux over 3 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Add ability to uncheck or remove attributes from existing transfer

Transfers are initially added by searching and then selecting elements then attributes to add. When we want to edit the transfer, we are only able to remove entire elements, not by attributes. This became an issue when we later found that we had a...
Hege Dammen over 1 year ago in PI to CONNECT / General 0 No status

Error handling for OPC UA Server nodes with "Null" data type

Using a combination of Honeywell Experion OPC UA and the Aveva OPC UA Adapter, we have observed that when an instrument physically fails in the field or goes offline / stops sending communication to the Experion server, it may appear in the Honeyw...
ChrisMcKee 8 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 Evaluating

Add a parameter to disable NTLM authentication

On the "Health endpoints parameters" page of the documentation of any AVEVA Adapter, it states that Negotiate (i.e. try Kerberos first and fall back to NTLM if that fails) will be used if a username/password pair and a clientId/clientSecret pair a...
Guest 2 months ago in AVEVA™ Adapters / General 0 No status

Transformation and Scaling for OPC UA Adapter

Implement transformation and scaling for OPC UA adaptor the way it exists for PI OPC DA interface tags. The user can modify egressed tags and the data will be transformed / scaled when egressed.
Guest about 4 years ago in AVEVA™ Adapters 4 Future consideration

PI Adapter for AspenTech IP21

We have customers who are using AspenTech IP 21 and would like to have data replicated in both PI DataArchive and OCS in the future. Since the PI Interface is a bit outdated, a new PI Adapter would make perfect sense (since there is already a PI C...
Guest about 4 years ago in AVEVA™ Adapters / New Connectivity 4 Tell us more

Please add a feature for the OPC UA adapter to enable the adapter to only store values with a good status or rather filtering out bad values

When receiving bad values from the OPC UA Server to the adapter there is no option to filter out bad values. So these values get stored in the Data Archive and are causing problems with analyses (e.g. expression or Event Frame generation). At the ...
Guest over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 No status