Skip to Main Content
CONNECT feedback portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about CONNECT products and services. All of the feedback you share here is monitored and reviewed by the CONNECT product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for CONNECT. For links to our other feedback portals, please see RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Include [optional] unit of measure in the data selection configuration.

Some data sources do not provide a unit of measure. It would be useful to be able to specify the unit of measure as part of the data configuration so that this information is provided to EDS/PI/ADH through the data flow.
Mike Horrocks over 2 years ago in AVEVA™ Adapters / General 1 No status

host adapter(s) as a service

SaaS solution for customers with benefits thereof.
Glenn Moffett almost 3 years ago in AVEVA™ Adapters / General 1 No status

Do not bundle PI Adapters with EDS

Reduce the footprint of EDS by not bundling adapters with EDS but instead have them be a separate installation so only the desired adapters end up being installed on the device. It will also allow easier for a clearer process when an adapter needs...
Guest about 4 years ago in AVEVA™ Edge Data Store / Installation 1 Future consideration

read files from AWS S3, Azure storage and Google Cloud Storage

For example, model inference data is written to storage and required destination is a PI System.
Guest about 4 years ago in AVEVA™ Adapters / New Connectivity 0 No status

Support for "RTU over TCP" for Modbus Adapter using MBAP header

Challenge: Today, the PI Adapter for Modbus TCP does not natively support " RTU over TCP". It does support Modbus TCP, so as long as the "bridge" properly converts Modbus RTU to Modbus TCP (including the MBAP header), it should work fine. If the b...
Hans-Otto Weinhold about 3 years ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 No status

Provide additional time formatting options for RDBMS Queries

Background: Today we are collecting data from our AspenTech IP21 Server thorugh the PI Adapter for OPC UA and the related AspenTech OPC UA Server. This works perfectly fine for analogue data but not for data which is providing us equipment status ...
Hans-Otto Weinhold about 3 years ago in AVEVA™ Adapters / AVEVA Adapter for RDBMS 1 Tell us more

If data contains asset information, this data shall be written to asset related streams

Challenge: We have (CSV) data files which come from Laboratory or other measuring equipment where the data lines contain information on which asset the measurement was taken from. In our particular use case, we read sample data from lab analyzer w...
Hans-Otto Weinhold about 3 years ago in AVEVA™ Adapters / AVEVA Adapter for Structured Data Files 1 No status

Better support of IP21 OPC UA Server with PI Adapter for OPC UA

We have been using the PI Adapter for OPC UA in its current version to collect data from IP21 OPC UA Server during a lighthouse project. However, the configuration was a bit cumbersome since the OPC UA Server of AspenTech uses an opaque mechanism ...
Hans-Otto Weinhold over 3 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Create the possibility to organize streams in a folder structure.

Challenge: As a customer I use namespaces of ADH to separate data for different business units or sites located in specific regional locations (US, EMEA, ASIAPAC). But in the corresponding locations I need to have a possibility to organize data st...
Jeff Branfield over 3 years ago in Streams / SDS Explorer 0 No status

PI Adapter for Structured Files - User friendly interface

Make the configuration experience more user friendly. Add a user interface for adapter configuration and management.Today, this adapter is too configuration intensive
Rene Thomassen over 3 years ago in AVEVA™ Adapters / AVEVA Adapter for Structured Data Files 1 No status