Skip to Main Content
CONNECT feedback portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about CONNECT products and services. All of the feedback you share here is monitored and reviewed by the CONNECT product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for CONNECT. For links to our other feedback portals, please see RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

OIDC Authentication

Could you add to the current list of supported authentication methods ("basic" & "kerberos") the OIDC authentication ? This was asked as an example by one of my customers.
Guest over 2 years ago in Developer Resources / PI Web API Samples 0 No status

AVEVA Adapter for WITSML

We need an Adapter for WITSML to get data from drilling, completions, and interventions of oil wells to CONNECT data services, so the data can be shared between multiple stakeholders.
John Marriott over 2 years ago in AVEVA™ Adapters / New Connectivity 0 No status

change Http code 101 message from "No Content" to "Switching Protocols" on PI Web API

Hi AVEVA Team we found the issue about PI Web API. Once a client making connection to PIWebAPI over websocket (open chanel), PiWebAPI response with "HTTP code 101 No Content" instead of "HTTP code 101 Switching Protocols" Can we change response me...
Guest over 2 years ago in Developer Resources / PI Web API Samples 0 No status

Allow the BACnet Adapter to handle responses with an LVT that does not match the request

Currently the BACnet Adapter expects devices to respond with the same "Length Value, and Type" (LVT) value as the request. When this occurs the BACnet Adapter cannot parse the data in the response. For example: Request from Adapter, LVT=1 Response...
Guest over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for BACnet 0 No status

Addition of substitution parameters in DefaultStreamIdPattern -> specify a ValueField for it to read from

People wanting to use a single EventHub and Container holding events from many sources with common attribute naming. Want to be able to differentiate the naming of the pi tags based on source. Being able to substitute a unique source identifier (s...
Guest over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for Azure Event Hubs 0 No status

Error message should be generated for the Modbus request time out

After request time out, Modbus adapter should generate an error as time out after specified duration set by user.
Guest almost 3 years ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 No status

PI Adapters should not overwrite parameters configured in the stream in ADH

When we change any override parameters for a stream in ADH an adapter restart will overwrite what we configure in the stream. One example is changing the interpolation method for a stream in ADH because we want to see the trend as step. Every time...
Fabio Dani over 3 years ago in AVEVA™ Adapters / General 0 No status

Allow setting default security for all streams resulting from a given transfer

CONNECT may have multiple PI to CONNECT transfers coming from different Data Archives. The DAs data may have different security requirements. To facilitate managing this in CONNECT, there should be a way to set default security for streams (and as...
Brian Deslatte over 3 years ago in PI to CONNECT / General 0 No status

Automate dataset selection for each PI to CONNECT Agent

We would end up with more than 60+ PI to CONNECT Agents to configure. We have a strong AF hierarchy across our sites and could perfectly prepare a unique AF rootpath to select the relevant dataset to push from PI/AF to CONNECT for each 60+ connect...
Christian Leroux over 3 years ago in PI to CONNECT / General 1 Future consideration

Automate silent installation sequence

We have 60+ sites, each with PI/AF Servers. We intent to deploy a PI to CONNECT Agents locally at each sites to federate our PI data in ADH. We need a supported mechanism to automate the installation sequence at each 60+ sites and connect/register...
Christian Leroux over 3 years ago in PI to CONNECT / General 0 Already exists