Skip to Main Content
CONNECT feedback portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about CONNECT products and services. All of the feedback you share here is monitored and reviewed by the CONNECT product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for CONNECT. For links to our other feedback portals, please see RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Error message should be generated for the Modbus request time out

After request time out, Modbus adapter should generate an error as time out after specified duration set by user.
Guest over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 No status

PI Adapters should not overwrite parameters configured in the stream in ADH

When we change any override parameters for a stream in ADH an adapter restart will overwrite what we configure in the stream. One example is changing the interpolation method for a stream in ADH because we want to see the trend as step. Every time...
Fabio Dani over 3 years ago in AVEVA™ Adapters / General 0 No status

Don't change product version information response structure

The design of the /productinformation response has changed between EDS 2020 and EDS 2023 Patch 1. Our application missed the new position of the version string so I had to change code to catch it. I know the product has shipped so there is nothing...
Guest over 3 years ago in AVEVA™ Edge Data Store / General 1 Declined

Accept HEX numbers for Register offsets in data selection

Most modbus equipment providers provide information using registers in Hex format i.e. 0x0000 ~ 0xFFFF. It would be nice if the offset could accept this to avoid error in conversions HEX to DEC. Would make things alot more seamless/easier.
Guest over 3 years ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 Future consideration

ORC, parquet and avro file format support

Customer files from on-premises systems are delivered to the cloud in ORC format for ingestion into Data Hub
Glenn Moffett about 4 years ago in AVEVA™ Adapters / AVEVA Adapter for Structured Data Files 0 No status

Swagger.json v0.3.1.0 CTP 2 shows errors in Swagger Editor

Swagger.json in EDS Version 0.3.1.0 CTP 2 produces semantic errors when trying to generate a client using Swagger editor
Guest about 4 years ago in AVEVA™ Edge Data Store / General 0 Declined

Retrieve EDS Data Egress Status through REST API call

It would be great to have a REST API call available in EDS to get the current data egress state rather looking it up through the logfiles. The idea is to get information about when data was (successfully) egressed to OCS, AVEVA Data Hub or the PI ...
Guest about 4 years ago in AVEVA™ Edge Data Store / Egress 1 Tell us more

Add OMF Ingress URL to documentation and Token UI

As a OMF developer, I would like a single place to grab my Publisher Token and copy the OMF Ingress URI so that it's easier to configure my application.
Gregg Le Blanc about 4 years ago in Developer Resources / Open Message Format (OMF) 0 Declined

Provide authoritative advice/document on how to configure/connect ESBs to stream to OMF

In transportation, a common pattern is to use an ESB to gather all field data and make it the central point for interoperability. Examples include: JMS bus, Tibco ESB, HP OMi + IIB of Kafka, others. I believe it should be possible to configure tho...
Guest about 4 years ago in Developer Resources / Open Message Format (OMF) 0 Declined

OMF: Response code 200

Response code 200 for OMF or possibility for validating of OMF data. EDS send only ‘accepted’ not ‘finished without error’, even if OMF is malformed and dropped in processing. Customer needs 100% tracking, so we must read all data after sending ...
Guest about 4 years ago in Developer Resources / Open Message Format (OMF) 0 No status