To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for CONNECT. For links to our other feedback portals, please see RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Root Element should be added to the transfer

When we create a transfer from PI AF there is a way to select a Root Element to start the search. However the root element from where we start the search is not added to the transfer. Ideally we would be able to add the root element into the trans...
Fabio Dani 9 months ago in PI to CONNECT / General 0 No status

Support derived templates

When replicating AF data to CONNECT, I would like to make sure that all assets configured from templates which are themselves based on derived templates, preserve the template inheritance. For instance, if I have a Mobile Equipment template, with ...
Max McKay almost 2 years ago in PI to CONNECT / General 0 No status

Select subset of element attributes in PI to Connect transfer configuration

Hello, In order to set-up a small PoC use case on our site, we wanted to transfer a "selected" set of AF element attributes into AVEVA Connect, in order to integrate it further with our Databricks environment. However, we are forced to transfer th...
Steven Bouillart about 1 year ago in PI to CONNECT / General 0 No status

Support of Event Frame Annotations

Sometimes, annotations in Event Frames are stored (e.g. when acknowledging/commenting a notification in PI Vision). This information should get replicated to CONNECT data services and be made available through CONNECT visualization services. The o...
Hans-Otto Weinhold about 1 year ago in PI to CONNECT / General 0 No status

select element attributes to include in transfer

manage transfer shape and size
Glenn Moffett almost 4 years ago in PI to CONNECT / General 2 No status

transfer element attribute description

For example for PI Point Data Reference and String value types.
Glenn Moffett 8 months ago in PI to CONNECT / General 0 No status

Automatically detect new AF Elements and replicate them to CONNECT

As an AF Administrator, when I add new equipment to our plant and create new elements/attributes in AF to represent that equipment, I want that to be automatically replicated to CONNECT so I don't have to manually update a PI to CONNECT transfer t...
Guest about 4 years ago in PI to CONNECT 2 Future consideration

Make the Agent recrawl the AF/PI Point database from scratch

Make the agent recrawl the AF/PIPoint database from scratch every now and again and update its cache if required. I think this is what PI Vision does, so it doesn't have these limitations.
Guest about 1 year ago in PI to CONNECT / General 0 No status

Allow partitioning configuration for virtual tables

Databricks allows for specification of partitioning configuration on a deltatable. In some cases, this can improve query performance when querying the deltashare. It would be nice if on the virtual table, partitioning options were available which ...
Adam Fink 9 months ago in Data Platform Integration / Virtual Tables & Shares 0 No status

Configure refresh interval start time

End-users of created virtual tables expect updates at specific times.Request would enable user to indicate when refresh should occur. For example, for daily refresh, indicating a time of 5am, so that end-users can query the updated table when they...
Glenn Moffett about 1 year ago in Data Platform Integration / Virtual Tables & Shares 0 No status