To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for CONNECT. For links to our other feedback portals, please see RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Support for Stream ID Changes Across Environments

Currently, a customer has set up a new PI Data Archive to test the Communities feature in CONNECT Data Services. This new PI Data Archive is in a different environment from their production system. After testing, the customer is satisfied with the...
Willy Seah over 1 year ago in PI to CONNECT / General 0 No status

host adapter(s) as a service

SaaS solution for customers with benefits thereof.
Glenn Moffett almost 3 years ago in AVEVA™ Adapters / General 1 No status

PI to CONNECT for digital tags: Make it easier to distinguish real digital state values vs system digital states

PI to CONNECT creates a CONNECT stream type for PI digital tags with a property called DigitalStateName. This property includes both the "real" value of the tag's digital state set, but also the System Digital State (No Data, Error, Comm Fail, etc...
Elizabeth McErlean about 4 years ago in PI to CONNECT 0 No status

read files from AWS S3, Azure storage and Google Cloud Storage

For example, model inference data is written to storage and required destination is a PI System.
Guest about 4 years ago in AVEVA™ Adapters / New Connectivity 0 No status

Provide alternative message to 'No value defined"

When querying AF Element Information certain values display: "No value defined." and customer reaction was that there was something not working correctly/error that needed to be investigated. Suggestion was to change text to either show the value ...
Glenn Moffett almost 3 years ago in PI to CONNECT / General 0 No status

Support for "RTU over TCP" for Modbus Adapter using MBAP header

Challenge: Today, the PI Adapter for Modbus TCP does not natively support " RTU over TCP". It does support Modbus TCP, so as long as the "bridge" properly converts Modbus RTU to Modbus TCP (including the MBAP header), it should work fine. If the b...
Hans-Otto Weinhold about 3 years ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 No status

Provide additional time formatting options for RDBMS Queries

Background: Today we are collecting data from our AspenTech IP21 Server thorugh the PI Adapter for OPC UA and the related AspenTech OPC UA Server. This works perfectly fine for analogue data but not for data which is providing us equipment status ...
Hans-Otto Weinhold about 3 years ago in AVEVA™ Adapters / AVEVA Adapter for RDBMS 1 Tell us more

If data contains asset information, this data shall be written to asset related streams

Challenge: We have (CSV) data files which come from Laboratory or other measuring equipment where the data lines contain information on which asset the measurement was taken from. In our particular use case, we read sample data from lab analyzer w...
Hans-Otto Weinhold about 3 years ago in AVEVA™ Adapters / AVEVA Adapter for Structured Data Files 1 No status

AF Attribute not recongized in CONNECT transfer configuration if PI point data reference config string contains a datatype

We encountered an issue with PI to CONNECT (using current version of the Agent 2.2) not recognizing AF Attributes with PI Point Data References which have the pointtype in the data reference configuration. So that means if there is a config string...
Guest over 3 years ago in PI to CONNECT / General 0 No status

Better support of IP21 OPC UA Server with PI Adapter for OPC UA

We have been using the PI Adapter for OPC UA in its current version to collect data from IP21 OPC UA Server during a lighthouse project. However, the configuration was a bit cumbersome since the OPC UA Server of AspenTech uses an opaque mechanism ...
Hans-Otto Weinhold over 3 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status