To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for CONNECT. For links to our other feedback portals, please see RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Sampling/Publishing Interval parameters to be part of Data Selection description

When configuring the AVEVA Adapters in general, we would find more convenient to be able to define the ‘Sampling Interval’ and 'Publishing Interval' parameters inside the ‘Data Selection’ configuration per each data stream. For instance, when desc...
Christian Leroux over 3 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Add failover / high availability for the PI to AVEVA Data Hub Transfer Agent

Right now, the Transfer Agent is a single point of failure. We need to be able to install at least one additional Transfer Agent, on a separate host, so that we can guarantee that our PI System data will arrive in AVEVA Data Hub. This will also al...
Daniel Lopez about 3 years ago in PI to CONNECT / General 0 No status

Support "Data Handling" options for adapters

The PI Interface for OPC DA can write IO timeout when it cannot get values from the OPC server. It would be useful to have the same option for the adapters so that stale data is marked IO timeout or similar, and automatically invalidates calculati...
Mike Horrocks over 1 year ago in AVEVA™ Adapters / General 1 No status

PI Adapter for AspenTech IP21

We have customers who are using AspenTech IP 21 and would like to have data replicated in both PI DataArchive and OCS in the future. Since the PI Interface is a bit outdated, a new PI Adapter would make perfect sense (since there is already a PI C...
Guest about 4 years ago in AVEVA™ Adapters / New Connectivity 4 Tell us more

Pi adapter OPCua able to rename pi-tags

As per title
Guest 11 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 3 Tell us more

Add ability to uncheck or remove attributes from existing transfer

Transfers are initially added by searching and then selecting elements then attributes to add. When we want to edit the transfer, we are only able to remove entire elements, not by attributes. This became an issue when we later found that we had a...
Hege Dammen almost 2 years ago in PI to CONNECT / General 0 No status

Add option to view user's effective permissions or view CONNECT as user

For data sharing with orgs that are not PI users, they would have to be added to the existing org's tenant. In this use case it is difficult to verify that a user has correct permissions and can only see data intended for them without using a test...
Adam Bolin 9 months ago in PI to CONNECT / General 0 No status

Classic Mode for Adapters

One of the big issues we have with adapters (outside of the lack of write capability) is not having the same control over creating and editing tags that we have with PI interfaces. As we talked about the adapter automatically creates PI tags or us...
Guest over 3 years ago in AVEVA™ Adapters / General 5 Future consideration

Allow AVEVA Adapter for Modbus TCP to collect data on INT64 and UINT64 registers

Certain equipment is providing energy data under INT64 or UNIT64 register types. However, the Adapter currently only supports FLOAT64, which is not compatible. We want to be able to configure the Adapter for Modbus TCP to collect data on INT64 and...
Alexa Derago about 1 year ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 Future consideration

Adapter for BACnet - defaultStreamIdPattern add ObjectName as possible parameter

Currently, for the Adapter for BACnet its [Data source parameters] defaultStreamIdPattern does not have an option to include the ObjectName in the defaultStreamIdPattern. It would be good to include this as a possible parameter for the defaultStre...
Guest 7 months ago in AVEVA™ Adapters / AVEVA Adapter for BACnet 0 No status