Skip to Main Content
CONNECT feedback portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about CONNECT products and services. All of the feedback you share here is monitored and reviewed by the CONNECT product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for CONNECT. For links to our other feedback portals, please see RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Enable AVEVA Adapter for OPC UA to work with OPC UA Servers that only allow Dynamic Addressing and Virtual Browsing

Some OPC UA Servers have the concept of Dynamic Namespace Addressing and Virtual Browsing. The UA Nodes do not exist in the OPC UA Address Space. Nodeids are created\added to the Address Space only when a Client makes a request for the NodeIds thr...
Guest 9 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Allow setting interpolation type in Adapters

We would like to be able to specify the interpolation type (linear vs step) when Adapter creates tags in Archive.
Guest over 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Be able to reorder components

As an AVEVA Adapter gets used more, some components might need to be added or deleted, which can leave the component list in a suboptimal order. Please allow the components to be reordered, ideally by clicking and dragging for the most frictionles...
Kenneth Barber 3 months ago in AVEVA™ Adapters / AVEVA Adapter Configuration Utility 0 No status

Do not have data entry where only 1 choice is allowed (e.g. component type when adding a new component)

In the AVEVA Adapter Configuration Utility, when you try to add a new component to an AVEVA Adapter, you get a dropdown menu for the component type. However, there is only 1 choice: the AVEVA Adapter component type. The only required instance of t...
Kenneth Barber 3 months ago in AVEVA™ Adapters / AVEVA Adapter Configuration Utility 0 No status

For PI Points created by AVEVA Adapters, use the point class "base" instead of "classic" if the PI Point does not use "classic"-specific PI Point attributes

When an AVEVA Adapter creates a new PI Point, it always uses the point class "classic", even if none of the attributes that are specific to this point class are ever used. Instead, AVEVA Adapters should create PI Points using the point class "base...
Kenneth Barber 3 months ago in AVEVA™ Adapters / General 0 No status

Be able to configure history recovery through the AVEVA Adapter Configuration Utility for AVEVA Adapters that support history recovery (e.g. OPC UA, RDBMS)

This is item #3 of this suggestion, posted as its own suggestion.
Kenneth Barber 3 months ago in AVEVA™ Adapters / AVEVA Adapter Configuration Utility 0 No status

Be able to configure the Client Failover Service through the AVEVA Adapter Configuration Utility or a separate optional GUI program

The Client Failover Service suffers from the same issues as AVEVA Adapters before the AVEVA Adapter Configuration Utility was released: you need to constantly check against the documentation and make sure that you spelled parameters and their valu...
Kenneth Barber 3 months ago in AVEVA™ Adapters / AVEVA Adapter Configuration Utility 0 No status

Ua Server force failover / improve failover logic

Let me preface this by saying that I know it is a workaround for a non-compliance with the OPC UA specifications. The point is that the situation described below is unfortunately all too common and the workaround is needed. It often happens that t...
Guest over 3 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 No status

Prevent PI Adapter for OPC UA from modifying/override stream overrides and metadata upon restart

Problem: I have configured PI Adapter for OPC UA to collect data from an OPC UA Server. Since UoMs are not assigned properly, I created stream overrides in AVEVA Data Hub to assign the proper UoM to the particular stream. I also associated stream ...
Hans-Otto Weinhold over 3 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 4 In development

List of groups assigned to a user required

Requirements: In the Aveva portal : https://connect.aveva.com/#/account/home 1>User management tab: Export of the users list to excel along with their assigned groups in separate columns. see attached snapshot "User_Report.png" 2>Flex credit...
oberoi pereira 3 months ago in Administration / Reporting 0