To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for CONNECT. For links to our other feedback portals, please see RESOURCES below.

ADD A NEW IDEA

Clear

Connectivity

Include more details in Transfer Health Stream

The TransferStatus property of the Transfer Health Stream currently does not show warning messages generated during a transfer. It is limited to messages like "Stopped", "Started" or "Initializing". This makes it difficult for end users to detect ...
Derek Wong 4 months ago in PI to CONNECT / General 0 No status

PI Adapters should handle good NULL Values like PI Connectors and submit to the archive

A PI Connector reading a Null value in good quality send it to the Archive A PI Adapter skip the value, this gives in the archive a wrong picture. please enable the PI Adapter to submit also Null values with good quality to the archive like PI Con...
Guest 7 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 2 No status

Show all schedule parameters in the schedule table

Schedules have only 3 parameters: ID, period, and offset, but only ID and period are shown in the table. Please show the offset in the table as well so that we can get, at a glance, a complete overview of all schedules for an AVEVA Adapter instance.
Guest about 2 months ago in AVEVA™ Adapters / AVEVA Adapter Configuration Utility 0 No status

PI Tag Mapping configuration in the background of PI OPC UA Adapter to use Point ID

The CSV / JSON file in the background will have the mapping between the OPC UA Server tag against its' respective PI Tag Name. In such case, if we need to change the tag name after sometime, then which results in multiple process like stop the Ada...
Guest 5 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 No status

Allow multiple instances of an AVEVA Adapter to exist on the same server without using Docker

Currently, there can be only 1 instance of a specific AVEVA Adapter on each server if Docker is not used. However, within that instance, multiple components and data sources can be configured. This is convenient, but then the service account for t...
Guest 2 months ago in AVEVA™ Adapters / General 0 No status

PI Adapter for OPC UA Array Support

As a PI System Administrator, I would like for the PI Adapter for OPC UA to support array data types from the OPC UA Server. A large amount of our data may be contained within arrays on our OPC UA Server, so we would not currently be able to colle...
Guest about 4 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 12 No status

Allow remote configuration

Adapters are currently only listening on localhost (127.0.0.1) causing them to be only accessible locally. For docker containers, they can only be accessed from within the container or directly on the host (with the --network host switch which res...
Guest about 4 years ago in AVEVA™ Adapters / General 4 Future consideration

Allow the PI Point description to not be populated by the adapter

Implement a configuration flag that allows one to NOT synchronize description from OPC UA server into PI Tag. In instances where the description is empty "", the description cannot be set in PI. Similarly, the description on the OPC UA Server sid...
Guest about 4 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 17 Planned

Start/stop components to be retained on restart

Currently it is possible to stop a component for a running adapter. However, if the adapter is restarted the component will automatically start up. It would allow for extra control during commissioning, downtime, incidents, etc. to be able to disa...
Mike Horrocks 10 months ago in AVEVA™ Adapters / General 0 No status

Include buffering metrics in adapter health

In the OmfEgress component in adapter health the metrics are limited to DeviceStatus, and IO rate. Another key metric for this component is the buffering state. To keep it simple it would be useful to have the number of events in the buffer. This ...
Mike Horrocks over 1 year ago in AVEVA™ Adapters / General 1 No status