Skip to Main Content
CONNECT feedback portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about CONNECT products and services. All of the feedback you share here is monitored and reviewed by the CONNECT product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for CONNECT. For links to our other feedback portals, please see RESOURCES below.

ADD A NEW IDEA

Clear

Connectivity

Prioritize user-friendliness over reflecting the configuration file

Currently, the AVEVA Adapter Configuration Utility is a program that lets you enter data into the configuration file without having to type parameter names and while having some protection against invalid inputs (e.g. a check box for true/false va...
Kenneth Barber 4 months ago in AVEVA™ Adapters / AVEVA Adapter Configuration Utility 0 No status

Add a pop-up message in ACU to let user know if StreamId does not follow adapter stream id rules

Adapter creates the streamId during discovery based on {NamespaceIndex}.{Identifier} from the data source. If streamId does not follow rules from user guide or SDS rules user may not be able to view or add streamIDs to trend in CDS. Add a pop-up m...
Guest 2 months ago in AVEVA™ Adapters / AVEVA Adapter Configuration Utility 0 No status

Custom HTTP header

add functionality so will bepossible to configure the PI Adapter for OPC UA to include a custom HTTP header when authenticating requests to the PI Web API endpoint The request for this feature recently came up in a support case for PPC (Dev CR: CR...
Guest over 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 Future consideration

Change Power BI Connector Installation

Currently the Power BI Connector installs the connector under the ID doing the installation. I my Cooperate world, hardly any user has the right to install anything, and if they did it would be under an different Admin ID. Options for where it sho...
Guest about 1 month ago in PI to CONNECT / General 0 No status

Enable AVEVA Adapter for OPC UA to detect unchanged source values beyond a configured interval and continue sending the last known value with refreshed timestamps until a new source event is received

This enhancement is required so the AVEVA Adapter for OPC UA can functionally match ABB 800xA / Vtrin RTDB historical behavior while preserving existing PI System and Asset Framework functionality. The customer would like this capability implement...
Claudia Sischin 6 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Improve warning message handling for dynamic payloads in the adapter logs

When the MQTT Adapter is handling dynamic JSON payloads, there are a high number of warning messages that flood the adapter component message logs. To avoid taking up too much disk space and to make it easier to navigate the logs without digging t...

PI Adapter for OPC UA to support X509 client authentication

Add support for X509 client authentication to OPC UA servers
Guest 3 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Allow Multiple Data Archives per PI to CONNECT Agent

Allowing data transfer for tags from multiple PI Data Archives with one agent will help to cut down on the number of agent services, and therefore machines, that need to be involved to send data from PI to CONNECT.
Guest over 4 years ago in PI to CONNECT 0 In development

PI Adaptor for Perfmon

To move to next gen AVEVA tech, and perform a migration to Adaptors, critical monitoring with perfmon adaptor (Instead of Interface for PIPerfMon) would be ideal. Portability of using linux, docker etc. and having this data be available in AVEVA D...
Guest 8 months ago in AVEVA™ Adapters / New Connectivity 1 No status

AVEVA Adapter for MQTT to support payload compression from the source MQTT SparkplugB device

AVEVA Adapter for MQTT (SparkplugB data source) to support payload compression from the source MQTT SparkplugB device. Compression can be enabled at the Edge, for example Enable compression and/or aliasing at the Edge: For compression, either the ...
Ee Sheing Lee 6 months ago in AVEVA™ Adapters / AVEVA Adapter for MQTT 1 No status