To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for CONNECT. For links to our other feedback portals, please see RESOURCES below.

ADD A NEW IDEA

Clear

Connectivity

Support failover/high availability/redundancy/backup instances for the CONNECT To PI Agent

Please allow the CONNECT To PI Agent to have redundant/backup instances, similar to PI Collectives for the PI Data Archive, UniInt failover for PI Interfaces, and the failover of AVEVA Adapters.
Guest 3 months ago in CONNECT to PI 0 No status

Rename services to reflect the renaming of the product

AVEVA Adapters were previously called "PI Adapters", but the name of any AVEVA Adapter service begins with "PIAdapter". The PI To CONNECT Agent was previously called the "PI To Data Hub Agent", but the service name is still "PIToDataHubAgent". I'm...
Guest about 2 months ago in AVEVA™ Adapters / General 0 No status

PI to Connect Agent instance Failover

on behalf of customer: We would like to see agent failover added to PI to Connect. The PI System already provides high availability, and extending this capability into PI to Connect would deliver a resilient hybrid infrastructure end-to-end. Histo...
omar alomari 10 months ago in PI to CONNECT / General 1 No status

OPC UA Adapter Create Tag on Discovery

For the OPC UA Adapter, we are noticing that a tag won't be created until a data point comes in after the tag is added to the data filter. That causes issues for slow updating tags. For instance an open/shut valve that is rarely operated. We have ...
Guest about 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 Future consideration

Adapter for BACnet - defaultStreamIdPattern add ObjectName as possible parameter

Currently, for the Adapter for BACnet its [Data source parameters] defaultStreamIdPattern does not have an option to include the ObjectName in the defaultStreamIdPattern. It would be good to include this as a possible parameter for the defaultStre...
Guest 5 months ago in AVEVA™ Adapters / AVEVA Adapter for BACnet 0 No status

Automatic Configuration Sync between failover adapters

When adapters in a failover group, any changes to configuration need to be manually synchronised between the adapters. Without automation, this could lead to misaligned configuration causing data collection issues.
Mike Horrocks 4 months ago in AVEVA™ Adapters / General 0 No status

Support URI Builder attributes and make them clickable

Allow URI Builder attributes to be added to a transfer, then turn them into links in CVS dashboards. Even better if they can be used in text hyperlinks. That way you can jump from a CVS dashboard straight into a PI Vision display or some other web...
Guest 5 months ago in PI to CONNECT / General 0 No status

Add option to view user's effective permissions or view CONNECT as user

For data sharing with orgs that are not PI users, they would have to be added to the existing org's tenant. In this use case it is difficult to verify that a user has correct permissions and can only see data intended for them without using a test...
Adam Bolin 7 months ago in PI to CONNECT / General 0 No status

Pi adapter OPCua able to rename pi-tags

As per title
Guest 9 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 3 Tell us more

Support outputs/write data from PI Adapters

No description provided
Guest about 4 years ago in AVEVA™ Adapters / General 4 No status