Skip to Main Content
CONNECT feedback portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about CONNECT products and services. All of the feedback you share here is monitored and reviewed by the CONNECT product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for CONNECT. For links to our other feedback portals, please see RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Replication of tag attributes

Provide the possibility to manually select replication of tag attributes as stream metadata. Besides None, Low, Medium, High in the Stream Metadata Replication Policy of a transfer there should be a "Custom" option to select additional tag attribu...
Hans-Otto Weinhold 5 months ago in PI to CONNECT / General 0 No status

PI Tag Mapping configuration in the background of PI OPC UA Adapter to use Point ID

The CSV / JSON file in the background will have the mapping between the OPC UA Server tag against its' respective PI Tag Name. In such case, if we need to change the tag name after sometime, then which results in multiple process like stop the Ada...
Guest 7 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 No status

Bitmask Functionality in AVEVA PI OPC UA Adapter

During the migration from the PI OPC DA Interface to the AVEVA PI OPC UA Adapter, we noticed that the ability to apply bitmasks to incoming values is no longer supported. This functionality is critical in many existing implementations, especially ...
Guest over 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 Future consideration

Include more details in Transfer Health Stream

The TransferStatus property of the Transfer Health Stream currently does not show warning messages generated during a transfer. It is limited to messages like "Stopped", "Started" or "Initializing". This makes it difficult for end users to detect ...
Derek Wong 6 months ago in PI to CONNECT / General 0 No status

PI Adapter for OPC UA should poll a series of items based on a trigger events

Same as the PI Interface for OPC DA feature with "Trigger Tags", the idea is to poll for updates on a series of item streams (tags) only when a certain item stream updates. The benefit of this is to create timestamp alignments between a series of...
Guest about 4 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Add an option to disable endpoint validation between results of GetEndpoints and CreateSession

As discussed in OPC UA Adapter - Mismatch of Endpoints returned by GetEndpoints and CreateSession , in the OPC UA SDK 4.1.0+ endpoint validation was added to compare results returned in responses to GetEndpoints and CreateSession requests. The OPC...
Guest over 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 2 Planned

Custom HTTP header

add functionality so will bepossible to configure the PI Adapter for OPC UA to include a custom HTTP header when authenticating requests to the PI Web API endpoint The request for this feature recently came up in a support case for PPC (Dev CR: CR...
Guest over 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 Future consideration

Enable AVEVA Adapter for OPC UA to detect unchanged source values beyond a configured interval and continue sending the last known value with refreshed timestamps until a new source event is received

This enhancement is required so the AVEVA Adapter for OPC UA can functionally match ABB 800xA / Vtrin RTDB historical behavior while preserving existing PI System and Asset Framework functionality. The customer would like this capability implement...
Claudia Sischin 6 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Error handling for OPC UA Server nodes with "Null" data type

Using a combination of Honeywell Experion OPC UA and the Aveva OPC UA Adapter, we have observed that when an instrument physically fails in the field or goes offline / stops sending communication to the Experion server, it may appear in the Honeyw...
ChrisMcKee 10 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 2 Evaluating

Incorporate the concepts of PI System Directory and PI System Health into CONNECT

For a short while, OSIsoft had a program called "PI System Directory", which allowed you to monitor, from a web interface, which versions of which PI programs were installed on each PI server, among other things. PI System Directory Publisher had ...
Kenneth Barber about 1 month ago in PI to CONNECT / General 0 No status