To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for CONNECT. For links to our other feedback portals, please see RESOURCES below.

ADD A NEW IDEA

Clear

AVEVA™ Adapters

Prioritize user-friendliness over reflecting the configuration file

Currently, the AVEVA Adapter Configuration Utility is a program that lets you enter data into the configuration file without having to type parameter names and while having some protection against invalid inputs (e.g. a check box for true/false va...
Kenneth Barber 3 months ago in AVEVA™ Adapters / AVEVA Adapter Configuration Utility 0 No status

Allow the PI Point description to not be populated by the adapter

Implement a configuration flag that allows one to NOT synchronize description from OPC UA server into PI Tag. In instances where the description is empty "", the description cannot be set in PI. Similarly, the description on the OPC UA Server sid...
Guest about 4 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 17 Planned

Tag path in PI Point attribute

As a PI administrator or super user, I would like the AVEVA Adapter for OPC UA to capture the tag path (eg. Plant|Area|Unit|SubUnit|Equipment|Sensor) from the OPC UA model into an attribute of the PI Point, eg instrumenttag. This would make it eas...
Clement Dekeyser 29 days ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Browse data source model in AVEVA Adapter Configuration Utility for easier data selection

If my data source (such as an OPC UA server) exposes an asset model, then as a super user or administrator responsible for data selection with the AVEVA Adapter Configuration Utility, I would be able to browse it directly in the utility without in...
Clement Dekeyser 29 days ago in AVEVA™ Adapters / AVEVA Adapter Configuration Utility 0 No status

Additional columns to filter in data selection

As a super user or administrator responsible for data selection with the AVEVA Adapter for OPC UA and AVEVA Adapter Configuration Utility, I would need additional columns as filters: Path Description Data Type Min Max Engineering Units...
Clement Dekeyser 29 days ago in AVEVA™ Adapters / AVEVA Adapter Configuration Utility 0 No status

PI Tag Mapping configuration in the background of PI OPC UA Adapter to use Point ID

The CSV / JSON file in the background will have the mapping between the OPC UA Server tag against its' respective PI Tag Name. In such case, if we need to change the tag name after sometime, then which results in multiple process like stop the Ada...
Guest 7 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 No status

PI Adapter for OPC UA to support X509 client authentication

Add support for X509 client authentication to OPC UA servers
Guest about 2 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Bitmask Functionality in AVEVA PI OPC UA Adapter

During the migration from the PI OPC DA Interface to the AVEVA PI OPC UA Adapter, we noticed that the ability to apply bitmasks to incoming values is no longer supported. This functionality is critical in many existing implementations, especially ...
Guest over 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 Future consideration

Support https instead of http only

No description provided
Guest about 4 years ago in AVEVA™ Adapters / General 2 Future consideration

Start/stop components to be retained on restart

Currently it is possible to stop a component for a running adapter. However, if the adapter is restarted the component will automatically start up. It would allow for extra control during commissioning, downtime, incidents, etc. to be able to disa...
Mike Horrocks 11 months ago in AVEVA™ Adapters / General 0 No status