To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for CONNECT. For links to our other feedback portals, please see RESOURCES below.

ADD A NEW IDEA

All ideas

Enable AVEVA Adapter for OPC UA to detect unchanged source values beyond a configured interval and continue sending the last known value with refreshed timestamps until a new source event is received

This enhancement is required so the AVEVA Adapter for OPC UA can functionally match ABB 800xA / Vtrin RTDB historical behavior while preserving existing PI System and Asset Framework functionality. The customer would like this capability implement...
Guest 6 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Add an option to disable endpoint validation between results of GetEndpoints and CreateSession

As discussed in OPC UA Adapter - Mismatch of Endpoints returned by GetEndpoints and CreateSession , in the OPC UA SDK 4.1.0+ endpoint validation was added to compare results returned in responses to GetEndpoints and CreateSession requests. The OPC...
Guest over 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 2 Planned

Last Refresh Time column on the Virtual Table main page

Currently, Last Refresh Time of each table is available in CONNECT data services > Analytics > Virtual Tables, but clicking each table individually is required to see it. For troubleshooting and verifying healthy state of tables, having the ...
Miranda Hill 2 months ago in Data Platform Integration / Virtual Tables & Shares 0 No status

Custom HTTP header

add functionality so will bepossible to configure the PI Adapter for OPC UA to include a custom HTTP header when authenticating requests to the PI Web API endpoint The request for this feature recently came up in a support case for PPC (Dev CR: CR...
Guest over 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 Future consideration

Tag path in PI Point attribute

As a PI administrator or super user, I would like the AVEVA Adapter for OPC UA to capture the tag path (eg. Plant|Area|Unit|SubUnit|Equipment|Sensor) from the OPC UA model into an attribute of the PI Point, eg instrumenttag. This would make it eas...
Clement Dekeyser about 1 month ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Browse data source model in AVEVA Adapter Configuration Utility for easier data selection

If my data source (such as an OPC UA server) exposes an asset model, then as a super user or administrator responsible for data selection with the AVEVA Adapter Configuration Utility, I would be able to browse it directly in the utility without in...
Clement Dekeyser about 1 month ago in AVEVA™ Adapters / AVEVA Adapter Configuration Utility 0 No status

Additional columns to filter in data selection

As a super user or administrator responsible for data selection with the AVEVA Adapter for OPC UA and AVEVA Adapter Configuration Utility, I would need additional columns as filters: Path Description Data Type Min Max Engineering Units...
Clement Dekeyser about 1 month ago in AVEVA™ Adapters / AVEVA Adapter Configuration Utility 0 No status

Error handling for OPC UA Server nodes with "Null" data type

Using a combination of Honeywell Experion OPC UA and the Aveva OPC UA Adapter, we have observed that when an instrument physically fails in the field or goes offline / stops sending communication to the Experion server, it may appear in the Honeyw...
ChrisMcKee 10 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 2 Evaluating

iFrame Support within CONNECT visualization service (CVS)

Enable rendering of embedded iframe content within CVS dashboards or relevant UI components. This would provide a lightweight integration option without requiring more complex data transformations or additional tooling. Used case: We are looking...
Ee Sheing Lee 4 months ago in Content 0 No status

Allow custom time presets in CVS display

CVS already provides predefined time-range presets. It would be useful to allow display designers to modify these presets, including adding, removing or changing the available time ranges. For example, if a customer’s shifts start at 6:00 am, they...